Search results for "Voxel size"

showing 5 items of 5 documents

Some tests of 3D ultrasonic traveltime tomography on the Eleonora d'Aragona statue (F. Laurana, 1468)

2013

Abstract The use of a non-destructive technique in situ can be a valuable diagnostic tool to support verification of restoration, as well as a monitoring technique in works of art or historical monuments. We present a high resolution 3D ultrasonic tomography to one of the most important statues of the Regional Gallery of Palazzo Abatellis of Palermo, the bust of Eleonora d'Aragona by F. Laurana (1430–1502). This technique allowed to study the structural continuity of the material of the marble. Some tests have been carried out to optimize inversion parameters, such as voxel size and to choose between straight and curved rays. We propose to calculate a minimum lateral resolution using the sa…

Ultrasonic measurements 3D tomography Inversion tests Lateral resolution Voxel size Raytracingbusiness.industry3d tomographyLateral resolutionGeophysicsOpticsHomogeneousUltrasonic TomographyUltrasonic sensorStatueTomographybusinessVoxel sizeGeology
researchProduct

Multiscale three-dimensional imaging of intact human organs down to the cellular scale using hierarchical phase-contrast tomography

2021

ABSTRACTHuman organs are complex, three-dimensional and multiscale systems. Spatially mapping the human body down through its hierarchy, from entire organs to their individual functional units and specialised cells, is a major obstacle to fully understanding health and disease. To meet this challenge, we developed hierarchical phase-contrast tomography (HiP-CT), an X-ray phase propagation technique utilising the European Synchrotron Radiation Facility’s Extremely Brilliant Source: the world’s first high-energy 4th generation X-ray source. HiP-CT enabled three-dimensional and non-destructive imaging at near-micron resolution in soft tissues at one hundred thousand times the voxel size whilst…

Phase contrast tomographyHuman healthThree dimensional imagingCoronavirus disease 2019 (COVID-19)Human kidneyHuman bodyTomographyBiologyVoxel sizeBiomedical engineering
researchProduct

Influence of voxel size on the accuracy of linear measurements of the condyle in images of cone beam computed tomography: A pilot study

2018

Background To analyze the influence of voxel size and exposure time on the accuracy of linear measurements of the condyle. Material and methods Four macerated hemi-mandibles of pigs were scanned in nine different voxel size protocols. Three-dimensional models of the condyle were generated in order to establish a comparison between linear measurements obtained with each voxel protocol and those obtained with a caliper (gold standard). The comparison between the protocols was performed considering the average of the two measurements of the condyle in the latero-medial (LM) and antero-posterior (AP) axes and also through repeated measurement ANOVA with rank transformation. The level of signifi…

Cone beam computed tomographyResearchLinear measurement030206 dentistryGold standard (test):CIENCIAS MÉDICAS [UNESCO]computer.software_genreCondyle03 medical and health sciences0302 clinical medicineVoxel030220 oncology & carcinogenesisUNESCO::CIENCIAS MÉDICASMedical imagingCalipersOral SurgeryGeneral DentistrycomputerVoxel sizeBiomedical engineeringMathematicsJournal of Clinical and Experimental Dentistry
researchProduct

Three-dimensional image analytical detection of intussusceptive pillars in murine lung

2015

A variety of diseases can lead to loss of lung tissue. Currently, this can be treated only symptomatically. In mice, a complete compensatory lung growth within 21 days after resection of the left lung can be observed. Understanding and transferring this concept of compensatory lung growth to humans would greatly improve therapeutic options. Lung growth is always accompanied by a process called angiogenesis forming new capillary blood vessels from preexisting ones. Among the processes during lung growth, the formation of transluminal tissue pillars within the capillary vessels (intussusceptive pillars) is observed. Therefore, pillars can be understood as an indicator for active angiogenesis …

HistologyComputer scienceAnatomyMathematical morphologyPathology and Forensic MedicineResectionMurine lungCapillary vesselssense organsTomographyLung tissueProcess (anatomy)Voxel sizeBiomedical engineeringJournal of Microscopy
researchProduct

Assessment of fractures in endodontically treated teeth restored with and without root canal posts using high-resolution cone beam computed tomography

2020

Abstract Background: Root fractures are a diagnostic challenge for dentists because their signs and symptoms are not present in all cases, and they are difficult to differentiate from endodontic treatment failures, the purpose of the present study was to determine the relationship between the characteristics of tooth fractures and the presence of root canal posts in endodontically treated teeth using high-resolution cone beam computed tomography (CBCT). Methods: Fifty high-resolution CBCT scans of endodontically treated teeth with a diagnosis of fracture were obtained, of which 30 were from women and 20 were from men. These scans were acquired with three Veraviewepocs 3D units and one 3D Ac…

OrthodonticsCone beam computed tomographybusiness.industryResearchRoot canalTooth FractureHigh resolution030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Operative Dentistry and Endodontics030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicinemedicine.anatomical_structurestomatognathic systemUNESCO::CIENCIAS MÉDICASFracture (geology)MedicineCANAL RADICULARRoot canal postsbusinessGeneral DentistryVoxel size
researchProduct